Инструкции за употреба на продукта

Въведение:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.

Изисквания за настройка:

  • Datasheet of the desired pixel fixture
  • Computer to access the device settings page
  • For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
  • For DIN PIXIE: EMU Software for configuration

Guide to Custom Protocol Creation:

  1. Verify datasheet for compatible pixel protocol
  2. Navigate to the Device’s User Interface to enablethe  custom protocol feature
  3. Adjustthe  pixel fixture’s data voltage timing viathe  web interface based othe n datasheet

Step 1: Verify Datasheet for Compatible Protocol

  1. Check the data transmission method from the datasheet
  2. Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
  3. Choose a supported protocol with a similar data transmission method

СЪВМЕСТИМ ФЪРМУЕР

Създаването на персонализиран протокол е представено в следните контролери за пиксели ENTEC:

SKU Продукт Версия на фърмуера
73539 DIN PIXIE V2.0 или по-нова версия
70067 ПИКСЕЛАТОР МИНИ V2.0 или по-нова версия
70068 PIXELATOR MINI MK2 V1.0 или по-нова версия
71521 OCTO MK2 V4.0 или по-нова версия
71522 OCTO MK3 V1.0 или по-нова версия

ВЪВЕДЕНИЕ

  • ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
  • Тази функция позволява на потребителите да регулират силата на звукаtage синхронизация въз основа на поддържаните протоколи, ако методът за предаване на данни съвпада с някой от поддържаните от нас протоколи.
  • Този документ предоставя инструкции за настройка за създаване на потребителски пикселен протокол и проверка на критериите.

ИЗИСКВАНИЯ ЗА НАСТРОЙКА

Следното е необходимо за създаване на персонализиран протокол:

  1. Лист с данни: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
  2. Устройство: Use a computer to access the device settings page.
  3. For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
  4. For DIN PIXIE: Use the EMU Software for configuration.

РЪКОВОДСТВО ЗА СЪЗДАВАНЕ НА ПЕРСОНАЛИЗИРАН ПРОТОКОЛ

Тази функция позволява на потребителите да коригират обема на даннитеtage timing to meet specific protocol needs. To create a custom protocol:

  1. Проверете листа с данни за съвместимия пикселен протокол.
  2. Отидете до потребителския интерфейс на устройството, за да активирате функцията за персонализиран протокол.
  3. Коригирайте обема на данните на пикселното приспособлениеtage синхронизиране чрез web интерфейс според листа с данни на производителя.

Стъпка 1: Проверете листа с данни за съвместимия протокол

  1. Проверете метода за предаване на данни на желания от вас протокол от листа с данни.
    1. The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
      • Най-често срещаният метод предава данни без допълнителни битове (напр. D1-D2-D3…Dn).
        Example: Информация, взета от листа с данни на WB2812B

        ENTTEC-73539-DIN-PIXIE-FIG-2

      • Някои протоколи, като TM1814, включват допълнителни данни отпред (напр. C1-C2-D1-D2…Dn).
        Example: Информация, взета от листа с данни на TM1814

        ENTTEC-73539-DIN-PIXIE-FIG-3

  2. Посочете съответстващия протокол, поддържан от устройството (или изберете от горния напрample) that shares the same data transmission method as your desired pixel protocol.
  3. Продължете към стъпка 2 за допълнителна конфигурация.

Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)

  1. Access to the OCTO/PIXELATOR MINI web интерфейс
    1. Google Chrome се предлага като web browser to access the OCTO/PIXELATOR MINI’s web интерфейс.
    2. Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC webсайт www.enttec.com, за да изтеглите приложението.
    3. After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

      ENTTEC-73539-DIN-PIXIE-FIG-4
      Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
      See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.

  2. Navigate to the Settings page – Output Setting.
    Отидете до изхода, към който е свързано желаното пикселно приспособление. Изберете пикселен протокол от падащия списък, който споделя същия метод на предаване, проверен в Стъпка 1.

    ENTTEC-73539-DIN-PIXIE-FIG-5

  3. Enable Custom protocol (Continue to Step 3)
    Активирайте квадратчето за отметка „По избор“ за достъп до данните томtage настройка на времето. Премахнете отметката, за да деактивирате персонализирания протокол.

    ENTTEC-73539-DIN-PIXIE-FIG-6

За DIN PIXIE

  1. Свържете DIN PIXIE към компютър чрез USB Type-B.
  2. Стартирайте софтуера EMU.
  3. Сканирайте за устройството и щракнете върху Conf на открития DIN PIXIE.

    ENTTEC-73539-DIN-PIXIE-FIG-6

  4. Enable Custom Protocol (Continue to Step 3)
    Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.

    ENTTEC-73539-DIN-PIXIE-FIG-8

Стъпка 3: Задайте персонализиран обtage синхронизиране

  1. Съвпадение на обtage тайминга в листа с данни на желания от вас протокол. Персонализираният протокол изисква 4 входа за попълване на обtage настройка на времето:
    Voltage Timing Definition
    Бит 0 високо време (T0H) Томътtagмного време, необходимо за код 0.
    Бит 1 високо време (T1H) Томътtagмного време, необходимо за код 1.
    Overall Bit Time: Общият обемtage time for a single bit.

    Lower limit = T0H+T0L

    Upper limit = T1H+T1L

    Нулиране на времето Общият обемtagКратко време, необходимо за нулиране на предаването на данни между всяка партида данни.

    ENTTEC-73539-DIN-PIXIE-FIG-9

  2. Лист с данни – Data voltage информация за времето Прample
    От листа с данни на WB2818B
    • Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage времеви диапазон.
    • Попълнете обtage времеви диапазон в персонализираното поле в настройките на изхода.

      ENTTEC-73539-DIN-PIXIE-FIG-10

ВАЖНО

  • ENTTEC recommends taking the median value of the range for the start.
  • Потребителят ще трябва да ЗАПАЗИ настройките, за да влезе в сила променената стойност.
  • Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
  • ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
  • Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.

ЗАКЛЮЧЕНИЕ

  • Това ръководство демонстрира как да настроите персонализиран протокол за отговарящи на условията устройства ENTEC и предостави технически познания за проверка на листа с данни на желаните от вас пикселни устройства.
  • Следвайки тези стъпки, потребителите могат да създадат персонализиран пикселен протокол, който не е намерен в падащия списък, без да чакат техническа поддръжка или нова версия на фърмуера. Ако имате въпроси или трудности при намирането на правилната информация, свържете се с нашия приятелски екип за поддръжка в местните офиси.

ЧЗВ

How do I access the device settings page on my computer?

You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web браузър.

Can I create a custom protocol without the datasheet?

It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.

Документи / Ресурси

ENTTEC 73539 DIN PIXIE [pdf] Ръководство за употреба
DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3, 73539 DIN PIXIE, 73539, DIN PIXIE, PIXIE

Референции

Оставете коментар

Вашият имейл адрес няма да бъде публикуван. Задължителните полета са маркирани *